Order Guide
The Bowen Series is available in 3 different configurations. These are: –
- BL Series – Made from 1.5mm thick stainless steel
- BM Series – Made from 1.5mm thick stainless steel, but with a 2mm thick enclosure door
- BW Series – Made from 2mm thick stainless steel
The different product configurations are shown in the table below.
Part Number | Height (mm) | Width (mm) | Depth (mm) | Usable Depth* (mm) | CAD Blocks | Enquiry |
---|---|---|---|---|---|---|
BL040320/S | 400 | 300 | 200 | 179 | Enquiry | |
BL040420/S | 400 | 400 | 200 | 150 | Enquiry | |
BL060420/S | 600 | 400 | 200 | 150 | Enquiry | |
BL060630/S | 600 | 600 | 300 | 250 | Enquiry | |
BL080630/S | 800 | 600 | 300 | 250 | Enquiry | |
BL120830/S | 1200 | 800 | 300 | 250 | Enquiry | |
BM040320/S^ | 400 | 300 | 200 | 179 | Enquiry | |
BM040420/S^ | 400 | 400 | 200 | 150 | Enquiry | |
BM060420/S^ | 600 | 400 | 200 | 150 | Enquiry | |
BM060630/S^ | 600 | 600 | 300 | 250 | Enquiry | |
BM080630/S^ | 800 | 600 | 300 | 250 | Enquiry | |
BM120830/S^ | 1200 | 800 | 300 | 250 | Enquiry | |
BW040320/S^ | 400 | 300 | 200 | 179 | Enquiry | |
BW040420/S | 400 | 400 | 200 | 150 | Enquiry | |
BW060420/S^ | 600 | 400 | 200 | 150 | Enquiry | |
BW060630/S^ | 600 | 600 | 300 | 250 | Enquiry | |
BW080630/S | 800 | 600 | 300 | 250 | Enquiry | |
BW120830/S | 1200 | 800 | 300 | 250 | Enquiry |
* Mounting pan to insides of door
^ Available on request
Downloads
Accessories
- Lock options
- Hinged escutcheon – 2mm zinc coated steel (White)
- Light kit brackets
- LED Light
Climate Control
AS/NZS 61439 Compliance
AS/NZS 61439 is the new series of standards for low-voltage (LV) switchgear and control gear assemblies. For more information on whether you need to comply see our AS/NZS 61439 page.
Click the bar below the requirements and responsibilities for complaince with AS/NZS 61439 for this enclosure.
The following definitions apply to this table: -
- Original Manufacturer* - Switchboard designer and manufacturer of the switchboard enclosure.
- Assembly Manufacturer* - A switchboard builder.
- Original Equipment Manufacturer - The company who manufactured the switchgear used in final assembly.
*The original manufacturer and assembly manufacturer can be the same company or different companies.
If you are a SWITCHBOARD BUILDER this means you are the ASSEMBLY MANUFACTURER and you may be the ORIGINAL MANUFACTURER too. Any switchgear you order will need to be covered by the requirements of the Original Equipment Manufacturer.
B&R has some (but not all) of the responsibilities of the ORIGINAL MANUFACTURER.
If you are an END USER of the equipment you can see who has responsibility from these definitions.
No | Characteristic to be Checked | Clause | Responsibility | Comments |
---|---|---|---|---|
1 | Strength of material and parts: | 10.2 | ||
Resistance to corrosion | 10.2.2 | Original Manufacturer | The Bowen Series of enclosures are made from Stainless Steel and as such do not have any corrosion effects as measured by the Standard thereby exceeding the comparative testing done. Plus, ES report; 103687. | |
Thermal stability (relates to non-metal enclosures) | 10.2.3.1 | Original Manufacturer | This clause refers mainly to plastic enclosures. | |
Resistance to abnormal heat and fire (due to internal electric effect) | 10.2.3.2 | Original Manufacturer | All insulating materials supplied have been tested to 960ºC glow-wire Standard. Plus, ES report; 103863 |
|
Resistance to ultra-violet (UV) radiation | 10.2.4 | Original Manufacturer | UV ratings refer mainly to plastic enclosures. Bowen enclosures are stainless steel and have zero UV degradation. | |
Lifting | 10.2.5 | Original Manufacturer | Lifting is verified by test, if required. Bowen enclosures are provided with lifting lugs rated to one tonne. |
|
Mechanical Impact | 10.2.6 | Original Manufacturer | IK10; Metal enclosure systems have been tested to exceed IK10 (20 Joules). | |
Marking | 10.2.7 | Assembly Manufacturer | Markings must be verified by test. Tests are performed by rubbing with water and petroleum spirits; generally done by the Switchboard Builder (Assembler). | |
2 | Degree of protection of enclosures (IP) | 10.3 | Original Manufacturer | IP66; Ingress Protection (IP) rating needs to be verified by test or by assessment. SIMTARS report; NE99/0034 |
3 | Clearances | 10.4 | Assembly Manufacturer | Clearance and creepage can only be verified by test. Switchboard Builders (Assembler) must maintain compliance by ensuring correct clearance and creepage distances are maintained at >8mm (Uimp=8kV) and >16mm (Ui=1kV) respectively. |
4 | Creepage distances | 10.4 | Assembly Manufacturer | |
5 | Protection against electric shock and integrity of protective circuits | 10.5 | ||
Effective continuity between the exposed conductive parts of the ASSEMBLY and the protective circuit | 10.5.2 | Assembly Manufacturer | Equipotential protective earth bonding points are required to be verified by test to less than 0.1ohm. Similar enclosure designs have been tested by Plus ES report; 103687. | |
Short-circuit withstand strength of the protective circuit | 10.5.3 | Original Manufacturer | The Bowen Series are generally understood to be fitted with equipment making the switchboard not exceed 10kA prospective short-circuit withstand rating (Icp). | |
6 | Incorporation of switching devices and components | 10.6 | Assembly Manufacturer | Points 6, 7 and 8 are largely the responsibility of the Switchboard builder (Assembler). It is a requirement that the Assembler follow guidance from the original manufacturer. The advice of original manufacturers such as B&R and switchgear manufacturers, needs to be adhered to. Switchboard Builders need to be aware of the Standard’s requirements for these verification points and incorporate these into complete design verification documentation. |
7 | Internal electrical circuits and connections | 10.7 | Assembly Manufacturer | |
8 | Terminals for external conductors | 10.8 | Assembly Manufacturer | |
9 | Dielectric Properties | 10.9 | ||
Power-frequency withstand voltage | 10.9.2 | Original Manufacturer | The Bowen Series of enclosures are provided as a basic empty enclosure and as such dielectric property verification has not been possible as internal configurations are not known. Dielectric properties need to be verified by Impulse withstand testing or by assessment. | |
Impulse withstand voltage | 10.9.3 | Original Manufacturer | ||
10 | Temperature-rise limits | 10.1 | Assembly Manufacturer | Temperature-rise can be determined by test or by comparison or by calculation. Temperature rise methods provided in AS/NZS 60890 can be used for switchboards not exceeding 1600A rating. The Bowen Series of enclosures are rated not to exceed 1600A and therefore AS/NZS 60890 should be used by the Designer. |
11 | Short circuit withstand strength | 10.11 | Original Manufacturer | The Bowen Series are generally understood to be fitted with equipment making the switchboard not exceed 10kA prospective short-circuit withstand rating (Icp). |
12 | Electromagnetic compatibility (EMC) | 10.12 | Original Equipment Manufacturer | Equipment installed in switchboards shall comply with the immunity requirements of the relevant product or generic EMC standard. The Switchboard builder (assembler) shall obtain from the device and or component manufacturer the specific performance criteria of the equipment based on the acceptance criteria given in the relevant standard. |
13 | Mechanical operation | 10.13 | Original Equipment Manufacturer | This verification testing need NOT be done on devices already been type tested according to their relevant product standard. Only if their mechanical operation has been modified does the assembly need to be retested by cycling it 200 times. |